Emission factor establishment for palm oil mill boiler
Nur H. Hanafi1, Mimi H. Hassim2, Yusuf Mohd, R. M3.
A study to establish the total particulate emission factor (EFs) from boiler of a palm oil mill plant
equipped with a multi-cyclones particulate arrestor was performed and reported in this
research. The mill employs a 500 kg steam/ h capacity of water-tube typed boiler and
processes 60 tonnes per hour of fresh fruit bunch (FFB). The samples of the dust were collected
iso-kinetically using the USEPA method 17 sampling train through a sampling port located after
a multidust cyclone unit. Results showed that the total dust generated from the boiler is 62.15
g/s and the calculated total dust emission factor based on the boiler capacity is 7.46 g/kg.
Poor combustion process is among the main factor that leads to the high particulate emission.
EFs data allows for early prediction of pollutants emission, which subsequently will assist in
determining the degree of control and the air pollution control system needed, besides
evaluating the effectiveness of the existing pollution control strategies. The establishment of EFs
for palm oil mills will definitely bring benefits for a better management of health and safety risks
in palm oil mills, now and in the future.
Affiliation:
- Universiti Teknologi Malaysia, Malaysia
- Universiti Teknologi Malaysia, Malaysia
- Universiti Teknologi Malaysia, Malaysia
Toggle translation
Download this article (This article has been downloaded 150 time(s))
|
|
Indexation |
Indexed by |
MyJurnal (2021) |
H-Index
|
6 |
Immediacy Index
|
0.000 |
Rank |
0 |
Indexed by |
Scopus 2020 |
Impact Factor
|
CiteScore (1.4) |
Rank |
Q3 (Engineering (all)) |
Additional Information |
SJR (0.191) |
|
|
|
|
|